AppLock is designed to be run on certain certified Windows CE based devices only. The AppLock program is installed as
part of the default software load and is configured with the Administration control panel.
Configuration parameters are specified by the AppLock Administrator for the Thor VM2 end-user. AppLock is password pro-
tected by the Administrator.
End-user mode locks the end-user into the configured application or applications. The end user can still reboot the mobile
device and respond to dialog boxes. The administrator-specified applications are automatically launched in the specified
order and run in full screen mode when the device boots up.
When the mobile device is reset to factory default values, for example after a cold reset, the Administrator may need to
reconfigure the AppLock parameters.
The assumption, in this section, is that the first user to power up a new mobile device is the system administrator.
Note: AppLock Administrator Control panel file Launch option does not inter-relate with similarly-named options contained
in other Thor VM2 Control Panels.
Note: A few applications do not follow normal procedures when closing. AppLock cannot prevent this type of application
from closing, but is notified that the application has closed. For these applications, AppLock immediately restarts the
application (see Auto Re-Launch) which causes the screen to flicker. If this type of application is being locked, the
administrator should close all other applications before switching to end-user mode to minimize the screen flicker.
AppLock is updated periodically as new options become available. Contact
availability.
Factory Default Settings - AppLock
Application
(page 5-23)
Filename
Title
Arguments
Order
Internet
Global Key
Global Delay
Input Panel
Application Launch Options
Auto at Boot
Auto at Boot Retries
Auto at Boot Delay
Auto Re-launch
Auto Re-launch Retries
Auto Re-launch Delay
Manual Launch
Allow Close
Security
(page 5-26)
Hotkey (Activation key)
Password
Options
(page 5-27)
Launch timeout
Blank
Blank
Blank
1
Disabled
Ctrl+Spc
10 sec
Disabled
(page 5-24)
Enabled
0
10 sec
Enabled
0
0 sec
Disabled
Disabled
Shift+Ctl+A
Blank
60000
Technical Assistance
(page 11-1) for update
5 - 19

Advertisement