(If an active High Auto-Dialer is used, then see section 12-59 to change the TTL output l
evel from the defaulted setting.)
8
Wiegand Input Connection from Another Compatible
Wiegand Reader (Separate purchase required)
Connect (+) wire of Reader to DC +12V (be sure that the existing power supply has eno
ugh capacity to support this accessory or upgrade to a sufficient one.)
Connect (-) wire of Reader to Power GND (-) wire.
Connect Wiegand output DATA0 wire of the additional Reader to DATA0, Pink wire.
Connect Wiegand output DATA1 wire of the additional Reader to DATA1, Cyan wire.
9

RS-232 Communication Port Connection

9-pin connector (COM Port, female) is required to connect serial communication RS-232 bet
ween Main Unit and Personal Computer.
Connect RS-232-TX, Black with White stripe wire of Main Unit to pin number 2 of 9-pin
connector.
Connect RS-232-RX, Red with White stripe wire of Main Unit to pin number 3 of 9-pin c
onnector.
Connect RS-232-GND, Black wire of Main Unit to pin number 5 of 9-pin connector.
Plug in 9-pin connector to COM1 or COM2 Port of Personal Computer.
Install and run STAR 100R Application Software.
10

Chime Bell Connection (Separate purchase required)

Connect (+) wire of Chime Bell unit to Bell Output, Brown with White stripe wire of Mai
n Unit.
Connect (-) wire of Chime Bell unit to Power GND (-) wire.
p.18