Closed Loop Control - Danfoss PVG 32 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 32:
Table of Contents

Advertisement

Technical Information
PVG 32 Proportional Valve Group
Electrical actuation

Closed loop control

©
Danfoss | August 2017
PVE characteristic - control by voltage
2.5V
5V
The PVE variants PVEA/H/M/S/U/P and the PVED-CC/-CX has a closed loop control supported by a spool
position sensor that ensures integrity towards flow forces and oil viscosity.
Hysteresus for PVE variants*
+8
+6
PVEM
PVEA
+4
+2
0
20%
-2
-4
-6
-8
* Hysteresis (control signal/spool travel) is indicated at rated voltage and f = 0.02 Hz. (one cycle = neutral
→ full A → full B → neutral)
The standard PVE's are proportional activated actuator except PVEO which is on/off. The PVE's have fault-
monitoring.
PVEU is available with PVEH and PVES hysteresis
PVEP, PVED-CC and PVED-CX are available with PVES hysteresis
The values are typical test data for exact ranges, see PVE Technical Information, 520L0553.
PVEP
control range
PVEU
7.5V
fixed
PVEH
PVES
2%
4%
~0%
157-504.10
520L0344 | BC00000038en-US0802 | 31