PVG 32 technical data

PVPX, electrical LS unloading valve

PVPX technical data
Max. operating pressure
Enclosure to IEC 529
Max. pressure drop at an oil flow of 0.1 l/min [2.6 US gal/min]
Oil temperature
(Inlet)
Max. coil surface temperature
Ambient temperature
Oil viscosity
Response time for LS pressure relief
Rated voltage
Max. premissible deviation from rated supply voltage
Current consumption at rated
voltage
Power consumption
©
Danfoss | August 2017
Fluids parameters
*
Oil viscosity
recommended range
minimum
maximum
Oil temperature
recommended range
minimum
maximum
Ambient temperature recommended range
Filtering in the hydraulic system
*
Max. start up viscosity 2500 mm²/s.
Recommended temperature
Min. temperature
Max. temperature
Operating range
Min. viscosity
Max. viscosity
at 22 °C [72 °F] coil temperature
at 110 °C [230 °F] coil temperature
at 22 °C [72 °F] coil temperature
at 110 °C [230 °F] coil temperature
12 - 75 mm²/s
4 mm²/s
460 mm²/s
30 - 60˚C
-30˚C
90˚C
-30° → 60°C
Max. allowed degree of contamination: 23/19/16
(ISO 4406, 1999 version)
350 bar [5075 psi]
IP65
2 bar [30 psi]
30 °C to 60 °C [86 °F to 140 °F]
-30 °C [-22 °F]
90 °C [194 °F]
155 °C [311 °F]
-30 °C to 60 °C [-22 °F to 140 °F]
2
12 to 75 mm
/s [65 to 347 SUS]
2
4 mm
/s [39 SUS]
2
460 mm
/s [2128 SUS]
300 ms
12 V
± 10%
1.55 A
1 A
19 W
12 W
520L0344 | BC00000038en-US0802 | 29
[65 - 347 SUS]
[39 SUS]
[2128 SUS]
[86 -140˚F]
[-22˚F]
[194˚F]
[-22° → 140°F]
24 V
0.78 A
0.5 A

Hide quick links: