Pvh, Hydraulic Actuation; Pvm, Mechanical Actuation; Pve, Electrical Actuation - Danfoss PVG 32 Technical Information

Proportional valve group
Hide thumbs Also See for PVG 32:
Table of Contents

Advertisement

Technical Information
PVG 32 Proportional Valve Group
PVG 32 technical data

PVH, hydraulic actuation

PVM, mechanical actuation

PVE, electrical actuation

26 |
©
Danfoss | August 2017
Technical data for PVH
Control range pressure
Max. pilot pressure
Max. pressure on port T (the hydraulic remote control lever should be
connected directly to tank.)
Operating torque for PVM
Spool displacement
Operating torque N•m [lbf•in]
PVM + PVMD
from neutral position
2.2 ±0.2
[19.5 ±1.8]
max. spool travel
2.8 ±0.2
[24.8 ±1.8]
into float position
away from float position
from any other position
No control lever position
Control lever range
Proportional control lever range
Control lever range – float position
For further information about PVE please see the Technical Information PVE, Series 4 for PVG 32/100/120 ,
520L0553.
Technical data for PVEO and PVEM
Supply voltage U
DC
Current consumption at rated voltage
Signal voltage (PVEM)
Signal current at rated voltage (PVEM)
Input impedance in relation to 0.5 • U
Power consumption
PVM + PVE
PVM + PVH
2.2 ±0.2
2.5 ±0.2
[19.5 ±1.8]
[22.1 ±1.8]
2.8 ±0.2
6.9 ±0.2
[24.8 ±1.8]
[61.0 ±1.8]
rated
range
max. ripple
neutral
A-port ↔ B-port
DC
5 – 15 bar [75 – 220 psi]
30 bar [435 psi]
10 bar [145 psi]
PVM + PVMR
PVM+PVMF
17
22
[3.8]
[5.0]
60 [13.5]
28 [6.3]
8.5 [73.3]
2 x 6
±19.5°
±13.4°
22.3°
12 V
24 V
DC
DC
11 V to 15 V
22 V to 30 V
5%
0.65 A @ 12 V
0.33 A @ 24 V
0.5 x U
DC
0.25 • U
to 0.75 • U
DC
DC
0.25 mA
0.50 mA
12 KΩ
8 W
520L0344 | BC00000038en-US0802