Technical Information
PVG 32 Proportional Valve Group
Electrical actuation
©
Danfoss | August 2017
PVHC characteristic - Spool stroke vs current
Spool stroke, mm
500/1000 mA
280/560 mA
PVHC current response and hysteresis @ 25 bar Pp, 21 ctS, 25 °C. The ideal curve is determined by the
main spool neutral spring. The PVHC has high hysteresis. The hysteresis is affected by viscosity, friction,
flow forces, dither frequency and modulation frequency. The spool position will shift when conditions are
changed e.g. temperature change.
7
6
5
4
3
2
1
0
280/560 mA
500/1000 mA
Ideal curve
Hysteresis
Current in mA
@ 12V
@ 24V
V310 000.A
520L0344 | BC00000038en-US0802 | 35