4-36 FI SYSTEM DIAGNOSIS

"C11" (P0340) CMP SENSOR CIRCUIT MALFUNCTION

DETECTED CONDITION
The signal does not reach ECM for 3 sec. or more,
after receiving the starter signal.
CMP sensor
When using the multi-circuit tester, do not strongly touch the terminal of the ECM coupler with
a needle pointed tester probe to prevent the terminal damage or terminal bend.
INSPECTION
1) Turn the ignition switch OFF.
2) Lift and support the fuel tank. (5-3)
3) Remove the air cleaner box. (5-14)
4) Check the CMP sensor coupler
If OK, remove the CMP sensor. (3-29)
5) Connect 3 new 1.5 V batteries in series, 1 kΩ resistor and the
multi-circuit tester as shown in the illustration.
\ 09900-25008: Multi-circuit tester set
W Tester knob indication: Voltage ()
• CMP sensor circuit open or short
• CMP sensor malfunction
• ECM malfunction
Bl
W
B
for loose or poor contacts.
POSSIBLE CAUSE
R
B/Y
B/Br
W
ECM
VCC
CMP
E2
1 kΩ
Bl
B