Byte 0: Multiplier for the Velocity (V)

Bit 0 to 7:
You must enter a binary value between 1 and 255 in byte 0. You can
calculate the stepping rate according to the following formula:
f
=
A
BV =
V
=
R
=
Note:
You can enter values from 1 to 255 for the multiplier. The maximum stepping
rate with a base value of BV =800 Hz is then 204 kHz. The IP 267 cannot
generate stepping rates lower than the preset start/stop rate (f
stepping rates are corrected to the value of f
4-10
f
(Hz) =
BV(Hz) *
A
Stepping rate of the motor
Base value for the frequency ( Table 4-4.)
Multiplier for the velocity (1 to 255)
Reduction factor (1 or 0.1). The factor is determined in the
current positioning job
ss
V
R
*
.