IP 267
Addressing and Programming
The values for frequency and acceleration/deceleration in Table 4-4. only apply if
you set reduction factor 1 in the positioning job (bit R="0"). Divide the values
given by 10 (bit R="1") for reduction factor 0.1. The pulse duration is not
affected by this.
4.1.6

Deleting the Configuration

An existing IP 267 configuration can be deleted by sending a new job with the
velocity 0 and operating mode "STOP" to the IP 267 following transmission of a
positioning job (Bit IQA = 0). The module then switches over to the "Non-
configured" state; the LEDs on the front darken. The IP needs to be reconfigured
before it can process any positioning jobs.
4
4-7
EWA 4NEB 812 6061-02a