Status Displays; 9-Way Subminiature D Female Connector For; Frontplate Of The Ip - Siemens SIMATIC S5 Manual

Ip 267 stepper motor controller
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Module Description
3.6

Status Displays

After you have switched on the power supply and connected the emergency limit
switch (PD), you must transfer the user-specific configuration data (frequency
range, start/stop rate, time interval for acceleration and deceleration, operating
mode, selector signal for limit switch configuration) to the IP 267. The module can
only accept positioning jobs when it has received a valid configuration message
frame. This is indicated by the green "RDY" LED on the frontplate ( Figure 3-4.)
and in the status bit of the feedback message frame. Another green "ACT" LED
signals pulse output in the case of a positioning job. The red "ABT" LED lights up
when positioning jobs have been interrupted e.g by the emergency limit switch
(PD).
ABT
U S
5V
ACT
RDY
6
STEPPER MOTOR
MODUL IP 267
6ES5 267-8MA11
1
2
3
4
5
6
3-8
Figure 3-4. Frontplate of the IP 267
Red Led
Sliding switch for
voltage selection
Green LED
Green LED
9-way subminiature D
female connector for
connecting a stepper motor
power section
EWA 4NEB 812 6061-02a
IP 267

Hide quick links: