IP 267
The control pulses are available at a 9-way subminiature D female connector on
the frontplate of the IP 267.
1
6
2
7
3
8
4
9
5
Figure 3-3. 9-Way Subminiature D Female Connector for Connecting the
Stepper Motor Power Sections (Terminal End)
Output Voltages:
When supplied with +5 V:
When supplied with V s :
(V s =5 V to 30 V)
Output current:
Stepping rate:
Numb. of steps:
Permissible cable length:
EWA 4NEB 812 6061-02a
Pin
Meaning
2
TN
Clock
4
TN N
Clock inverted
7
RP
Direction level
8
RP N
Direction level
inverted
9
NL
Ground
Signal 0
max. 0.4 V
Signal 1
min. 4.5 V
Signal 0
max. 0.4 V
Signal 1
min. V
20 mA (current-limited)
max. 204 kHz, independent of output voltage
20
max. 2
- 1 = 1 048 575 pulses / job
max. 50 m at 50 kHz, twisted wire pairs.
Module Description
- 0.4 V
s
3
3-7