Ip 267 stepper motor controller
Hide thumbs Also See for SIMATIC S5:
Table of Contents

Advertisement

Function block for assigning parameters to the IP 267
0059
:L
KF +2
005B
:JU
=M003
005C M008 :L
DW
3
005D
:L
KF +400
005F
:><F
0060
:JC
=M009
0061
:L
KF +1
0063
:JU
=M003
0064 M009 :L
DW
3
0065
:L
KF +800
0067
:><F
0068
:JC
=M010
0069
:L
KF +0
006B
:JU
=M003
006C M010 :S
F
100.0
006D
:L
FW 100
006E
:T
DW
20
006F
:BEU
0070 M003 :R
F
100.0
0071
:T
DR
18
0072
:L
DR
5
0073
:T
DL
18
0074
:L
DW
6
0075
:SLW
15
0076
:SRW
14
0077
:T
DR
17
0078
:L
DR
4
0079
:T
DL
17
007A
:L
FW 100
007B
:T
DW
20
007C
:BEU
007D M001 :***
7-8
YES :
KM 010
->
BYTE 3
BASE VALUE = 400 ?
YES :
KM 001
->
BYTE 3
BASE VALUE = 800 ?
YES :
KM 000
->
BYTE 3
ERROR NO.1 : BV ILLEGAL
STORE FB STATUS
BASE VALUE
->
TIME INTERVAL
->
LIMIT SWITCH CON.
->
FACTOR SS-RATE
->
STORE FB STATUS
EWA 4NEB 812 6061-02a
IP 267
BYTE 3
BYTE 2
BYTE 1
BYTE 0