Counter Name — Select the counter name from the drop down
options.
Sample Type — Select the sampling method for the selected variable
and comparing the value against the thresholds. The possible options
are:
Delta
The difference in the values is compared to the threshold.
Absolute
the end of the sampling interval.
Rising Threshold — Enter the rising counter value that triggers the
rising event alarm.
Rising Event — Select one of the previously-defined events.
Falling Threshold — Enter the falling counter value that triggers the
falling event alarm.
Falling Event — Select one of the previously-defined events.
Startup Event — Select the trigger that activates the alarm. The
possible options are:
Rising Alarm
Falling Alarm
Rising and Falling
the alarm.
Interval — Enter the alarm interval time in seconds. This is the
interval in seconds over which the data is sampled and compared with
the rising and falling thresholds.
Community — Enter the community to which the event belongs or
keep the default community.
Owner — Enter the event owner.
Description — Enter a description of the event.
Configure an Event
To configure events control:
1 Click Statistics and Diagnosis > Monitoring.
2 Click Threshold and Events.
D E L L C O N F I D E N T I A L – P R E L I M I N A R Y 8 / 9 / 1 6 - F O R P R O O F O N L Y
134
Statistics and Diagnostics
Guide\Dell_Astute_Statistics_and_Diagnostics.fm
— Subtracts the last sampled value from the current value.
— Compares the values directly with the thresholds at
— A rising counter value triggers the alarm
— A falling counter value triggers the alarm.
— Both rising and falling counter values trigger

Hide quick links: