Mounting the Device

The RUGGEDCOM RSG2100 is designed for maximum mounting and display flexibility. It can be equipped with
connectors that allow it to be installed in a 48 cm (19 in) rack, 35 mm (1.4 in) DIN rail, or directly on a panel.
IMPORTANT!
Heat generated by the device is channeled outwards to the enclosure. As such, it is recommended that
2.5 cm (1 in) of space be maintained on all open sides of the device to allow for some convectional
airflow.
Forced airflow is not required. However, any increase in airflow will result in a reduction of ambient
temperature and improve the long-term reliability of all equipment mounted in the rack space.
NOTE
For detailed dimensions of the device with either rack, DIN rail or panel hardware installed, refer to
Chapter 5, Dimension
CONTENTS
Section 2.5.1, "Mounting the Device to a Rack"
Section 2.5.2, "Mounting the Device on a DIN Rail"
Section 2.5.3, "Mounting the Device to a Panel"
Section 2.5.1

Mounting the Device to a Rack

The RUGGEDCOM RSG2100 can be secured to a standard 48 cm (19 in) rack using separately purchased rack
mount adapters. The adapters can be installed at the front or rear of the chassis.
Each adapter kit includes four adapters.
Mounting the Device
Drawings.
Chapter 2
Installing Device
9