Failsafe Relay Specifications; Supported Networking Standards - Siemens RUGGEDCOM RSG2100 Installation Manual

Hide thumbs Also See for RUGGEDCOM RSG2100:
Table of Contents

Advertisement

Chapter 4
Technical Specifications
Non-Hazardous Environments
Power Supply Type
24 VDC
48 VDC
h
HI (125/250 VDC)
h
HI (110/230 VAC)
e
(F) denotes fast-acting fuse
f
(T) denotes time-delay fuse.
g
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
h
The HI power supply is the same power supply for both AC and DC.
Section 4.2

Failsafe Relay Specifications

Rated Switching Current
Maximum Switching Capacity
Section 4.3

Supported Networking Standards

Standard
IEEE 802.3
IEEE 802.3u
IEEE 802.3x
IEEE 802.3z
IEEE 802.3ab
IEEE 802.3ad
IEEE 802.1D
IEEE 802.1D
IEEE 802.1p
IEEE 802.1Q
IEEE 802.1w
30
Input Range
Minimum
10 VDC
36 VDC
88 VDC
85 VAC
Parameter
Max Switching Voltage
10 Mbps Ports
100 Mbps Ports
ü
ü
ü
ü
ü
ü
ü
Maximum
36 VDC
72 VDC
300 VDC
264 VAC
2 A @ 240 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
1000 Mbps Ports
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
ü
e f
Internal Fuse Rating
6.3 A(F)
3.15 A(T)
2 A(T)
2 A(T)
Value (Resistive Load)
240 VAC, 125 VDC
150 W, 500 VA
Description
10BaseT/10BaseFL
100BaseTX/100BaseFX
Flow Control
1000BaseLX
1000BaseTx
Link Aggregation
MAC Bridges
Spanning Tree Protocol (STP)
Class of Service (CoS)
VLAN (Virtual LAN) Tagging
Rapid Spanning Tree Protocol (RSTP)
Failsafe Relay Specifications
RUGGEDCOM RSG2100
Installation Guide
Maximum Power
g
Consumption
28 W

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ruggedcom m2100

Table of Contents