Chapter 2
Installing Device
Section 2.7.2, "Wiring Examples"
Section 2.7.1

Connecting AC or DC Power

To connect a single high AC, high DC or low DC power supply to the device, do the following:
CAUTION!
Electrical hazard – risk of damage to equipment. Before testing the dielectric strength (HIPOT) in the
field, remove the metal jumper. This metal jumper connects transient suppression circuitry to chassis
ground and must be removed in order to avoid damage to transient suppression circuitry during
testing.
CAUTION!
Electrical hazard – risk of damage to equipment. Do not connect AC power cables to a DC power supply
terminal block. Damage to the power supply may occur.
IMPORTANT!
Each internal power module is labeled POWER 1 or POWER 2. Make sure to connect the power supply to
the corresponding internal power module.
1.
Remove the terminal block cover.
2.
Identify the internal power module (POWER 1 or POWER 2) appropriate for the power supply (AC or DC).
3.
Use these screws along with #6 ring lugs to secure the wires to the terminal block.
NOTE
For wiring options, refer to
4.
Connect the positive wire from the power source to the positive/live (+/L) terminal on the terminal block.
14
Section 2.7.2, "Wiring
Examples".
RUGGEDCOM RSG2100
Installation Guide
Connecting AC or DC Power