Connection Of The Digital Outputs - KEB COMBIVERT G6 Installation Manual

Control circuit io-link
Table of Contents

Advertisement

Input
Name
RST
ST
R
F
I1
I2
I3
I4

2.1.5.4 Connection of the digital outputs

Examples for the connection of the digital outputs
Output
Name
O1
O2
PIN
open-loop operation
5
6
7
8
10
Fixed frequen-
cy 1
9
Fixed frequen-
cy 2
12
11
Activates the DC braking
Connection appliance
14
13
15
Example for the control of digital inputs and outputs
Factory setting of the digital outputs
PIN
14
Switches at actual value=setpoint
13
Ready signal
Factory setting of the digital inputs
reset
Control release
Direction of rotation reverse
Direction of rotation forward
Fixed frequency
3
External error input (E.EF)
Connection to an external control
4
6 8
101214
3
5 7
9 11 13
Control circuit
closed-loop operation
Fixed value 1
Fixed value 3
Fixed value 2
14
13
15
DI2
DI1
COM
GB - 17

Advertisement

Table of Contents
loading

Table of Contents