Zoning Example - Cisco Nexus 5500 Series NX-OS Configuration Manual

Nx-os san
Table of Contents

Advertisement

Configuring and Managing Zones
Interface-based zoning only works with Cisco SAN switches. Interface-based zoning does not work for
Note
VSANs configured in interop mode.

Zoning Example

The following figure shows a zone set with two zones, zone 1 and zone 2, in a fabric. Zone 1 provides access
from all three hosts (H1, H2, H3) to the data residing on storage systems S1 and S2. Zone 2 restricts the data
on S3 to access only by H3. H3 resides in both zones.
Figure 31: Fabric with Two Zones
You can use other ways to partition this fabric into zones. The following figure shows another possibility.
Assume that there is a need to isolate storage system S2 for the purpose of testing new software. To achieve
this, zone 3 is configured, which contains only host H2 and storage S2. You can restrict access to only H2
and S2 in zone 3, and to H1 and S1 in zone 1.
Figure 32: Fabric with Three Zones
OL-30895-01
Cisco Nexus 5500 Series NX-OS SAN Switching Configuration Guide, Release 7.x
Information About Zoning
129

Advertisement

Table of Contents
loading

Table of Contents