479646
11
DIAGNOSTIC MODE
With the display On, press & hold KEY LOCK and WASH TEMP for 3 seconds.
To enter the DIAGNOSTIC MODE:
1.
Turn the mains on at the supply and on at the control panel.
2.
Press and hold the KEYLOCK
time two beeps will sound.
Diagnostic mode may be entered while the product is running.
In Diagnostic mode the following I/O's can be operated.
Toggle
Hot Valve
Cold Valve 1
Cold Valve 2
Rotate
Motor clockwise
Motor counter clockwise
Toggle
Door Lock On/Off
Heater On/Off
Toggle
Pump On/Off
Toggle
Recycle On/Off
Self Test Cycle
11.1
Self Test
Select the SPIN
•
88:88 appears in the display and the door will lock. Once the door locks, 77:77 appears in the display.
Press the START/PAUSE button
•
77:77 will remain in the display and the hot valve turns on.
Press the START/PAUSE button
77:77 still remains displayed and cold valve 1 "Main Wash" turns on.
•
Press the START/PAUSE button
•
77:77 still remains displayed and cold valve 2 "Pre-Wash" turns on.
Press the START/PAUSE button
77:77 still remains displayed and cold valve 1 + Cold Valve 2 "Softener" turns on and will keep filling
•
until the water level is correct for the heater test.
•
66:66 is displayed and the heater turns on for 10 seconds.
and WASH TEMP
I/O
cycle then press the WASH TEMP button to activate the test program.
buttons for at least 3 seconds, after which
Select
Everyday Cycle
Cotton Cycle
Heavy Cycle
Delicate
Easy Iron
Spin Cycle
30
Then Press
Wash Temp Button
Spin Button
Options Button
Wash Temp Button
Spin Button
Wash Temp Button
Spin Button
Wash Temp Button
Wash Temp Button
Wash Temp Button