13.1.8
Err 7:06
Error message: Motor Brown out Error
Trouble shooting:
The supply voltage has become too low to power the motor control module.
Measure / check the mains supply voltage is between
176 to 264 volts AC.
Turn machine off at the mains for 1 minute then turn
back on. Has error cleared?
Replace the motor control module.
Y
N
N
Y
41
Check another mains
outlet supply voltage.
Run a cycle.
479646