Size Setting Mode; Diagnostic Mode; Last Fault Data; Drain Pump Test - Fisher & Paykel Ecosmart GWL15-US-96200 Service Manual

Fisher & paykel ecosmart phase 7 electronic washing machines
Table of Contents

Advertisement

517792A
3

SIZE SETTING MODE

To set the size switch, turn the power on at the power point and off at the console. Press and hold
WASH TEMPERATURE SETTING UP then press POWER. EcoSmart
and the pattern of LEDs will change.
To lock the size into memory.
·
Press SPIN SPEED UP, the SPIN HOLD LED is on for 7.5 / 8.0kg (650mm wide).
·
Press POWER to confirm the setting and also exit this mode.
If the size setting is wrong, EcoSmart
·
The Auto Water Levels chosen may be incorrect.
·
The High Water Level may be incorrect by as much as 40mm.
·
The wash profiles may be incorrect resulting in poor wash performance or vigorous wash
actions causing tangling, splash over or excess linting.
·
Water saver settings.
4

DIAGNOSTIC MODE

To enter diagnostic mode follow the steps below.
1. Turn the power on at the power point but off at the machine.
2. Press and hold WASH TEMPERATURE SETTING DOWN and then press POWER until the
machine gives 2 short beeps and lights up.
3. Release the buttons after the beeps as the beeps indicate diagnostic mode has been entered.
4.1

Last Fault Data

When in diagnostic mode the last fault can be found by pressing the SPIN SPEED UP or DOWN
buttons until the HOLD and SLOW lights are illuminated. Binary can then be read from the wash
progress lights.
4.2

Drain Pump Test

GW Washer
When in diagnostic mode press REGULAR to activate the drain pump. To deactivate the pump,
press REGULAR again.
4.3

Water Valve Test

The water valves can be activated in diagnostic mode by pushing WASH TEMPERATURE
SETTING UP to activate the Hot Valve and WASH TEMPERATURE SETTING DOWN to activate
the Cold valve as with previous models.
Pressing each button once will activate the valve. To de-activate valve press the same button
again. This is also good to use when installing machines as it takes the shock out of the fittings
and seals and allows checking for leaks on the inlet hoses, both machine end and tap or super-tub
end.
Caution: Do not leave the machine unattended when either or both valves are operating.
â
will have the following settings incorrect: -
128 64 32
16
8
21
â
will give 4 short beeps
4
2
1