14

DIAGNOSTICS LEVELS

Diagnostics allows various information to be extracted from the machine while in diagnostics, which can be
used in both static, machine idle and dynamic machine running modes. There are a total of 15 different
levels associated with the washer that are listed in the accompanying table.
While in diagnostics, use the Delay Start + MORE & - LESS buttons to select the diagnostic level required.
E.g. If diagnostic level d09 (Bowl speed RPM) is selected, after 1 second the information that corresponds to
level d09 is displayed in the 7segment display.
Level
Diagnostic info Displayed
d 00
Last User Warning
d 01
Last User warning cycle count
d 02
Last User warning cycle position
d 03
Fault Code
d 04
Fault code cycle count
d 05
Fault cycle position
d 06
Current Temperature
d 07
Target Temperature
d 00: Last User Warning
The last user warning is displayed in the LED display.
d 01: Last User Warning Cycle Count
The cycle count at which the last user warning occurred, displayed as 1,000s, 100's, 10's & 1's.
E.g. For a cycle count of 1010 cycles
d 02: Last User Warning Wash Cycle Position
The wash cycle position of the last user warning
d
09
1 second later
Output Displayed on
Screen
01
02
03
2 5 0
Level
Diagnostic info Displayed
d 08
Cycle count
d 09
Bowl speed
d 10
Target Speed
d 11
Water level
d 12
Target Fill level
d 13
Display SW Version
d 14
M/C SW Version
d 15
Drum Clean cycle count
1 0 1 0
Cycle Position
Agitation
Rinse
Spin
57