Installation, Electrical - ProMinent Sigma 2 S2Cb Operating Instructions Manual

Diaphragm motor-driven metering pump
Hide thumbs Also See for Sigma 2 S2Cb:
Table of Contents

Advertisement

Installation
P_SI_0023
Fig. 21: Permissible alignment of the
bleeder valve
Diaphragm rupture sensor

7.2 Installation, electrical

General safety notes
What requires electrical installation?
34
CAUTION!
Warning against leaks
Feed chemical which remains in the overflow line at the
bleeder valve, can attack the valve or cause it to leak
Route the overflow line with a continuous slope and
moreover with the tube nozzle pointed downwards - see
Fig. 21.
CAUTION!
Danger resulting from unnoticed diaphragm rupture
If the pump has been ordered with an electric diaphragm rup‐
ture sensor, it still has to be installed.
Screw the enclosed diaphragm rupture sensor into the
liquid end (no seal necessary).
CAUTION!
Warning of unnoticed diaphragm rupture
Only above approximately 2 bar system back pressure is a
signal generated upon a diaphragm rupture.
Only rely on the diaphragm rupture sensor at back pres‐
sures greater than 2 bar.
WARNING!
Danger of electric shock
Unprofessional installation may lead to electric shocks.
All cable cores cut to length must be provided with cable
end sleeves.
The Installation, electrical of the device may only be
undertaken by technically trained personnel.
What requires electrical installation?
Level switch
n
Diaphragm rupture sensor, electrical (option)
n
Dosing monitor (option)
n
Relay (option)
n
External control
n
mA output (option)
n
Bus connector (option)
n
Timer (option)
n
Pump, power supply
n