Decommissioning - ProMinent Sigma 2 S2Cb Operating Instructions Manual

Diaphragm motor-driven metering pump
Hide thumbs Also See for Sigma 2 S2Cb:
Table of Contents

Advertisement

Decommissioning

13
Decommissioning
Decommissioning
78
WARNING!
Danger of an electric shock
When working on the motor or electrical auxiliary equipment,
there is a danger of an electric shock.
Before working on the motor, take note of the safety
instructions in its operating instructions!
Should external fans, servomotors or other auxiliary
equipment be installed, these should also be discon‐
nected and checked that they are voltage free.
WARNING!
Danger from chemical residues
There is normally chemical residue in the liquid end and on
the housing after operation. This chemical residue could be
hazardous to people.
It is mandatory that the safety note relating to the
"Storage, Transport and Unpacking" chapter is read
before shipping or transporting the unit.
Thoroughly clean the liquid end and the housing of
chemicals and dirt. Adhere to the safety data sheet for
the feed chemical.
WARNING!
Warning of dangerous or unknown feed chemical
Should a dangerous or unknown feed chemical be used: It
may escape from the hydraulic components when working
on the pump.
Take appropriate protective measures before working on
the pump (e.g. safety glasses, safety gloves, ...).
Observe the safety data sheet for the feed chemical.
Drain and flush the liquid end before working on the
pump.
CAUTION!
Warning of feed chemical spraying around
Feed chemical can spray out of the hydraulic components if
they are manipulated or opened due to pressure in the liquid
end and adjacent parts of the system.
Disconnect the pump from the mains power supply and
ensure that it cannot be switched on again by unauthor‐
ised persons.
Depressurise the system before commencing any work
on hydraulic parts.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents