8.6.2 Settings for the "Calibrate" function (CALIBRATE menu)

Main menu
Mode
Settings
Service
Information
Language
Continuous
display
Calibrate
Settings
Batch
Auxiliary freq.
Calibrate
Dosing
End
The pump can also be operated in the calibrated state. In this case, the
corresponding continuous displays then indicate the metering volume or
the capacity directly.
Accuracy of the calibration
The calibration will not be accurate, if these conditions are
not adhered to:
Operate with at least 30 % stroke length.
The pump should operate at maximum frequency.
WARNING!
If the feed chemical is dangerous, take appropriate safety
precautions when executing the following calibration instruc‐
tions.
Observe the safety data sheet for the feed chemical!
1.
Lead the suction hose into a measuring cylinder containing the feed
chemical - the discharge hose must be installed in a permanent
manner (operating pressure, ...!).
2.
Prime using the feed chemical (simultaneously press the two
[arrow keys] ), should the suction hose be empty.
3.
Record the level in the measuring cylinder.
4.
To set the volume unit, follow the menu path
Units' .
è
5.
Using the
pressing the
6.
Select the
change to the first menu option.
7.
To start the calibration, press the
'Calib. running' appears, the pump starts to pump and indicates the
stroke rate (the pump works at the stroke rate, which is set under
'MANUAL' ).
8.
After a reasonable number of strokes (e.g. 200), stop the pump by
pressing the
9.
Determine the required metering volume (difference initial volume -
residual volume).
10.
Enter this volume in the menu option which appears and then press
[P/OK] - the pump changes to the main menu.
the key
Calibrate
32.90 mL
Start with OK
[arrow keys] , select the correct units and confirm by
[P/OK] key.
'CALIBRATE' menu and then use the [P/OK] key to
[P/OK] key. The next menu option,
[P/OK] key.
Set-up
Calibrate
Calibr. running
0107
Stop with OK
Calibr. quant.
0 0 0 3. 0 8 L
'Settings è System
55