Transporting Methods; Duty Cycle; Specifications - CIGWELD WELDSKILL 200HF Operating Manual

200 hf inverter
Table of Contents

Advertisement

200HF

2.08 Transporting Methods

These units are equipped with a handle for carrying
purposes.
ELECTRIC SHOCK can kill. DO NOT TOUCH
live electrical parts. Disconnect input
power conductors from de-energized
supply line before moving the welding
power source.
!
FALLING EQUIPMENT can cause serious
personal injury and equipment damage.
Lift unit with handle on top of case.

2.10 Specifications

Descriptio
Plant Part No
Power Source Dimensions
(excludes handle & gas nipple)
Power Source Mass
Cooling
Welder Type
Australian Standard
Number of Phases
Nominal Supply Voltage
Nominal Supply Frequency
Welding Current Range - TIG
Welding Current Range - Stick
Nominal DC Open Circuit Voltage
Factory Fitted Supply Plug Rating
Effective Input Current (I1eff )
(refer Note 2)
Maximum Input Current (I1max)
Minimum Single Phase Generator
Recommendation (refer Note 4)
STICK (MMAW) Welding Output, 40ºC, 10 min.
TIG (GTAW) Welding Output, 40ºC, 10 min.
Protection Class
INTRODUCTION
OPERATING MANUAL
WARNING
WARNING
n
Table 2-1: Specifications
Use handcart or similar device of adequate capacity.
If using a fork lift vehicle, place and secure unit on a
proper skid before transporting.

2.09 Duty Cycle

The rated duty cycle of a Welding Power Source,
is a statement of the time it may be operated at its
rated welding current output without exceeding the
temperature limits of the insulation of the component
parts. To explain the 10 minute duty cycle period the
following example is used. Suppose a Welding Power
Source is designed to operate at a 15% duty cycle,
90 amperes at 23.6 volts. This means that it has been
designed and built to provide the rated amperage
(90A) for 1.5 minutes, i.e. arc welding time, out of
every 10 minute period (15% of 10 minutes is 1.5
minutes). During the other 8.5 minutes of the 10
minute period the Welding Power Source must idle
and allowed to cool.
WeldSkill 200HF
W1008200
H245mm × W145mm × D420mm
8.2 kg
Fan Cooled
HF TIG, Lift TIG and Stick Multi Process Inverter
Power Source
AS 60974.1-2006 / IEC 60974-1
Single Phase
240 VAC ± 10%
50/60 Hz
10 - 200 A
10 - 180 A
15 Amps
15 Amps
33.9 Amps
7.6 kW
(9.5 kVA at 0.8 PF)
180 A @ 20%, 27.2 V
147 A @ 30%, 25.9 V
110 A @ 60%, 24.4 V
90 A @ 100%, 23.6 V
200 A @ 30%, 18.0 V
155 A @ 60%, 16.2 V
130 A @ 100%, 15.2 V
IP21S
2-4
75 V
Manual 0-5406

Advertisement

Table of Contents
loading

Table of Contents