Electromagnetic Compatibility - CIGWELD WELDSKILL 200HF Operating Manual

200 hf inverter
Table of Contents

Advertisement

200HF

3.06 Electromagnetic Compatibility

!
Extra precautions for Electromagnetic
Compatibility may be required when
this Welding Power Source is used in a
domestic situation.
A. Installation and Use - Users Responsibility
The user is responsible for installing and using the
welding equipment according to the manufacturer's
instructions. If electromagnetic disturbances are
detected then it shall be the responsibility of the user
of the welding equipment to resolve the situation
with the technical assistance of the manufacturer. In
some cases this remedial action may be as simple as
earthing the welding circuit, see NOTE below. In other
cases it could involve constructing an electromagnetic
screen enclosing the Welding Power Source and the
work, complete with associated input filters. In all
cases, electromagnetic disturbances shall be reduced
to the point where they are no longer troublesome.
NOTE
The welding circuit may or may not be
earthed for safety reasons. Changing the
earthing arrangements should only be
authorised by a person who is competent
to assess whether the changes will
increase the risk of injury, e.g. by allowing
parallel welding current return paths which
may damage the earth circuits of other
equipment. Further guidance is given
in IEC 974-13 Arc Welding Equipment -
Installation and use (under preparation).
B. Assessment of Area
Before installing welding equipment, the user shall
make an assessment of potential electromagnetic
problems in the surrounding area. The following shall
be taken into account
1. Other supply cables, control cables, signalling
and telephone cables; above, below and
adjacent to the welding equipment.
2. Radio and television transmitters and
receivers.
3. Computer and other control equipment.
4. Safety critical equipment, e.g. guarding of
industrial equipment.
5. The health of people around, e.g. the use of
pacemakers and hearing aids.
INSTALLATION
OPERATING MANUAL
WARNING
6. Equipment used for calibration and
measurement.
7. The time of day that welding or other activities
are to be carried out.
8. The immunity of other equipment in the
environment: the user shall ensure that other
equipment being used in the environment
is compatible: this may require additional
protection measures.
The size of the surrounding area to be considered
will depend on the structure of the building and other
activities that are taking place. The surrounding area
may extend beyond the boundaries of the premises.
C. Methods of Reducing Electromagnetic Emissions
1. Mains Supply
Welding equipment should be connected to the
mains supply according to the manufacturer's
recommendations. If interference occurs,
it may be necessary to take additional
precautions such as filtering of the mains
supply. Consideration should be given to
shielding the supply cable of permanently
installed welding equipment in metallic
conduit or equivalent. Shielding should be
electrically continuous throughout it's length.
The shielding should be connected to the
Welding Power Source so that good electrical
contact is maintained between the conduit and
the Welding Power Source enclosure.
2. Maintenance of Welding Equipment
The welding equipment should be routinely
maintained according to the manufacturer's
recommendations. All access and service
doors and covers should be closed and
properly fastened when the welding
equipment is in operation. The welding
equipment should not be modified in any way
except for those changes and adjustments
covered in the manufacturer's instructions. In
particular, the spark gaps of arc striking and
stabilising devices should be adjusted and
maintained according to the manufacturer's
recommendations.
3. Welding Cables
The welding cables should be kept as short
as possible and should be positioned close
together, running at or close to the floor level.
3-2
Manual 0-5406

Advertisement

Table of Contents
loading

Table of Contents