SENSORS

3.6.7 REPLACING THE TONER END SENSOR

1. Open the left cover [A].
2. Remove the AIO cartridge [B].
3. Remove the pawls on both sides of the toner end sensor [C] and remove the
sensor (" x 1).
[B]
[A]
H310R956.WMF
[C]
3-26
14 June, 2002
H310R958.WMF