Pin Description - Sharp XG-V10WU Technical Manual

4700lumens
Hide thumbs Also See for XG-V10WU:
Table of Contents

Advertisement

XG-V10WU
XG-V10WE

3-5-4. Pin description

Name
No.
I/O
Analog supply voltage of ADC A
AAVCC
62
I
Data output of ADC A (LSB: AD1, MSB:AD8)
AD8-AD1
6-13
O
Analog input of ADC A
AIN
63
I
Analog supply voltage of ADC B
BAVCC
51
I
Data output of ADC B (LSB: BD1, MSB:BD8)
BD8-BD1
17-24
O
Analog input of ADC B
BIN
50
I
Analog supply voltage of ADC C
CAVCC
30
I
Data output of ADC C (LSB:CD1, MSB: CD8)
CD8-CD1
36-43
O
Analog input of ADC C
CIN
31
I
Clock input. The clock frequency is normally 4 x the frequency subcarrier (fsc) for most video systems
CLK
56
I
The nominal clock frequency is 14.31818 MHz for National Television System Committee (NTSC) and 17.745 MHz for
phase alteration line (PAL).
Clamp enable. When using an internal clamp pulse, CLPEN should be high. When using an external clamp pulse,
CLPEN
57
I
CLPEN should be low.
Clamping bias current of ADC A. A resistor-capacitor combination that sets the clamp timing.
CLP OUT A
59
O
Clamping bias current of ADC B. A resistor-capacitor combination that sets the clamp timing.
CLP OUT B
54
O
Clamping bias current of ADC C. A resistor-capacitor combination that sets the clamp timing.
CLP OUT C
27
O
Clamping level of ADC A. A capacitor is connected to CLPV A to set the clamp timing. The clamp level at CLPV A is
CLPV A
60
O
connected to an output code of 16 (0010000).
Clamping level of ADC B. A capacitor is connected to CLPV B to set the clamp timing. The clamp level at CLPV B is
CLPV B
53
O
connected to an output code of 128 (1000000).
Clamping level of ADC C. A capacitor is connected to CLPV C to set the clamp timing. The clamp level at CLPV C is
CLPV C
28
O
connected to an output code of 128 (1000000).
Digital ground
DGND
15
I
Digital supply voltage
DVDD
26
I
EXTCLP
55
I
External clamp pulse input. When EXTCLP and CLPEN are low, the internal clamp circuit cannot be used.
The external clamp pulse when used is active high.
Ground of ADC A
GND A
64
I
Ground of ADC B
GND B
49
I
Ground of ADC C
GND C
32
I
Output initialized. The output data is synchronous when INIT is taken high from low. INIT is a control terminal that allows
INIT
58
I
the external system to initialize the TLC5733A data conversion cycle. INIT is usually used at power up or system reset.
Output format mode selector 0. When MODE1 is low and MODE0 is low, output data format1 is selected.
MODE0
46
I
When MODE1 is low and MODE0 is high, output data format2 is selected. When MODE1 is high and MODE0 is low,
output data format3 is selected. A high level on MODE1 and a high level on MODE0 is not used.
Output format mode selector 1. When MODE1 is low and MODE0 is low, output data format1 is selected.
MODE1
45
I
When MODE1 is low and MODE0 is high, output data format2 is selected. When MODE1 is high and MODE0 is low,
output data format3 is selected. A high level on MODE1 and a high level on MODE0 is not used.
NTSC/PAL control. NTSC/PAL should be low for NTSC and high for PAL.
NT/PAL
3
I
Output enable A. OE A enables the output of ADC A.
OEA
2
I
Output enable B. OE B enables the output of ADC B.
OE B
47
I
Output enable C. OE C enables the output of ADC C.
OE C
34
I
Digital ground for output of ADC A
QA DGND
5
I
Digital supply voltage for output of ADC A
QA DVDD
14
I
Digital ground for output of ADC B
QB DGND
25
I
Digital supply voltage for output of ADC B
QB DVDD
16
I
Digital ground for output of ADC C
QC DGND
44
I
Digital supply voltage for output of ADC C
QC DVDD
35
I
Bottom reference voltage of ADC A. The nominal externally applied dc voltage between RT A and RB A is 2 V for video
RB A
1
I
signals.
RB B
48
I
Bottom reference voltage of ADC B. The nominal externally applied dc voltage between RT B and RB B is 2 V for video
signals.
Bottom reference voltage of ADC C. The nominal externally applied dc voltage between RT C and RB C is 2 V for video
RB C
33
I
signals.
Top reference voltage of ADC A. The nominal externally applied dc voltage between RT A and RB A is 2 V for video
RT A
61
I
signals.
Top reference voltage of ADC B. The nominal externally applied dc voltage between RT B and RB B is 2 V for video
RT B
52
I
signals.
Top reference voltage of ADC C. The nominal externally applied dc voltage between RT C and RB C is 2 V for video
RT C
29
I
signals.
Description
30
Tied GND
Tied GND
Tied High
Tied GND
Tied GND
Tied GND
Tied GND
Tied GND

Advertisement