Sp-9Xxx (Etc) - Ricoh D127 Field Service Manual

Hide thumbs Also See for D127:
Table of Contents

Advertisement

SP-9XXX (Etc)

9001
Right Door Detect
001 0: NOT SET 1: SET
9901
Fusing Temperature Setting
010 Heater Force OFF Timing
Thresh: Warming-up Low
011
Temperature
012 Disable Change Time
013 Total Count Clear Time
014 Print Prepare Time
Target Temp revise (Temp)
9902
Sets the fusing additional temperature for the temperature correction. (Pattern A)
001 Added Temp: T1
002 Added Temp: T2
003 Added Temp: T3
004 Added Temp: T4
[0 to 1 / 0 ]
Selects the right door open/close SW ON/OFF
[0 to 99 / 17 / 1 mm/step ]
Sets the forced the heater OFF time after paper-
through.
[0 to 50 / 16 / 1 deg/step ]
Sets the basic temperature for determination of the
condition on machine-startup.
[0 to 999 / 5 / 1 sec/step ]
Unused. DO NOT change the setting.
[0 to 999 / 15 / 1 sec/step ]
When the wait time is over this SP's time, the following
three items are reset:
• Control cycle on printing,
• Repeat-temperature correction,
• CPM-down counter
[0 to 999 / 60 / 1 sec/step ]
Sets the print preparation time.
[0 to 50 / 5 / 1 deg/step ]
[0 to 50 / 15 / 1 deg/step ]
[0 to 50 / 10 / 1 deg/step ]
[0 to 50 / 5 / 1 deg/step ]
System Service Mode
139

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-c5D128

Table of Contents