5. Appendix: Fax Service Program
Initial Tx modem rate
Bit3
Bit2
0
0
0
0
0
0
0
0
0-3
0
1
0
1
0
1
1
1
1
1
1
1
Other settings: Not used
4-7 Not used
Switch 03
No
Inch-mm conversion before tx
Bit 1: 0, Bit 0: 0 = Inch-mm
conversion available
0-1
Bit 1: 0, Bit 0: 1 = Inch only
Bit 1: 1, Bit 0: 0 = Not used
Bit 1: 1, Bit 0: 1 = Disabled
DIS/NSF detection method
Bit 3: 0, Bit 2: 0 = First DIS or NSF
Bit 3: 0, Bit 2: 1 = Second DIS or
2-3
NSF
Bit 3: 1, Bit 2: 0 = Not used
Bit 3: 1, Bit 2: 1 = Disabled
262
Bit1
Bit0
bps
0
0
Not used
0
1
2400
1
0
4800
1
1
7200
0
0
9600
0
1
12000
1
0
14400
0
1
31200
1
0
33600
1
1
Disabled
FUNCTION
If training with a particular remote terminal
always takes too long, the initial modem rate
may be too high. Reduce the initial Tx modem
rate using these bits.
For the settings 14.4 or kbps slower, Switch 04
bit 4 must be changed to 0.
• Do not use settings other than listed on the
left. If the setting is "Disabled", the bit switch
setting is used.
Do not change the settings.
COMMENTS
The machine uses inch-based resolutions for scanning. If
"inch only" is selected, the printed copy may be slightly
distorted at the other end if that machine uses mm-based
resolutions.
If the setting is "Disabled", the bit switch setting is used.
(0, 1): Use this setting if echoes on the line are interfering
with the set-up protocol at the start of transmission. The
machine will then wait for the second DIS or NSF before
sending DCS or NSS.
If the setting is "Disabled", the bit switch setting is used.