Ricoh D127 Field Service Manual page 456

Hide thumbs Also See for D127:
Table of Contents

Advertisement

5. Appendix: Fax Service Program
Address
Function
PSTN busy tone frequency upper limit
680513
(high byte)
PSTN busy tone frequency upper limit
680514
(low byte)
PSTN busy tone frequency lower limit
680515
(high byte)
PSTN busy tone frequency lower limit
680516
(low byte)
PABX dial tone frequency upper limit
680517
(high byte)
PABX dial tone frequency upper limit
680518
(low byte)
PABX dial tone frequency lower limit
680519
(high byte)
PABX dial tone frequency lower limit
68051A
(low byte)
68051B
PABX dial tone detection time
68051C
PABX dial tone reset time (LOW)
68051D
PABX dial tone reset time (HIGH)
68051E
PABX dial tone continuous tone time
68051F
PABX dial tone permissible drop time
680520
PABX wait interval (LOW)
680521
PABX wait interval (HIGH)
680522
PABX ringback tone detection time
680523
PABX ringback tone off detection time
248
Unit
Remarks
If both addresses contain
Hz (BCD)
FF(H), tone detection is
disabled.
If both addresses contain
Hz (BCD)
FF(H), tone detection is
disabled.
If both addresses contain
Hz (BCD)
FF(H), tone detection is
disabled.
If both addresses contain
Hz (BCD)
FF(H), tone detection is
disabled.
If 68051B contains FF, the
machine pauses for the
pause time (680520 /
680521).
20 ms
-
20 ms
If both addresses contain
FF(H), tone detection is
20 ms
disabled.

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-c5D128

Table of Contents