5. Appendix: Fax Service Program
ITU-T T1 time (for PSTN G3 mode)
If the connection time to a particular terminal is longer than the NCU parameter setting, adjust this
byte. The T1 time is the value stored in this byte (in hex code), multiplied by 1 second.
Range:
0 to 120 s (00h to 78h)
FFh - The local NCU parameter factory setting is used.
Do not program a value between 79h and FEh.
Switch 01
No
Tx level
Bit4
Bit3
0
0
0-4
0
1
260
FUNCTION
Bit2
Bit1
Bit0
0
0
0
0
1
0
0
0
1
1
1
1
1
1
1
1
COMMENTS
If communication with a particular
remote terminal often contains errors,
the signal level may be inappropriate.
Adjust the Tx level for communications
0
with that terminal until the results are
–8
better.
If the setting is "Disabled", the NCU
–15
parameter 01 setting is used.
Disabled
• Do not use settings other than
listed on the left.