Sc9Xx - Ricoh D127 Field Service Manual

Hide thumbs Also See for D127:
Table of Contents

Advertisement

File Format Converter (MLB) error
A request to get access to the MLB
880
B
was not answered within the
specified time.
Administration area error
Defective the software.
This error occurs in the following
881
B
timing:
1. Giving a job to the printer
2. Login from the panel
3. Accessing from WEB browser
Software operation error (Receiving signal end)
Abnormal operation occurs in the
899
B
controller program (Hardware or
Software)

SC9xx

Electronic total counter error
900
B
The value of the total counter is out of
the normal range.
Printer error
920
C
An application error that stops the
machine operation is detected.
• MLB defective
• Caused by stored un-authentication
information in the software (NOT
caused by user operation)
1. Reboot the machine
1. Reboot the machine
2. Update the firmware.
3. If this SC does not clear with No.1, 2
processes, replace the controller
board.
• Defective NVRAM
• Defective software
1. Unexpected hardware resource
(e.g., memory shortage)
SC Tables
187

Advertisement

Table of Contents
loading

This manual is also suitable for:

S-c5D128

Table of Contents