Product Specifications

ID Flag Sensor
General Specifications
V680-HAM91/-HAM81
Item
Supply voltage
Power consumption
Ambient operating
temperature
Ambient storage
temperature
Ambient operating
humidity
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Dimensions
Degree of protection
Material
Weight
Mounting method
Interface cable
V680-A60 2M/5M/10M
Specifications
Interface cable
(Connector : 26pins)
The interface cable connector is not waterproof.
The maximum cable length is 10 m.
RFID System
74
User's Manual
Model
24 VDC +10%/-15%, Ripple (p-p): 10% max.
3.5 W max. (supply voltage: 24 VDC, current consumption: 0.15A Max., not included I/O Interface
current.)
-10 to 55°C (with no icing)
-25 to 65°C (with no icing)
25% to 85% (with no condensation)
20 MΩ min. (at 500 VDC) between terminals(except for FG) and casing
1,000 VAC, 50/60Hz for 1 min between terminals(except for FG) and casing
10 to 150 Hz, 0.2-mm double amplitude, acceleration: 15m/s
down, left/right, and forward/backward) for 8 minutes each
150 m/s
2
, 3 times each in 6 directions (Total: 18 times)
90 × 30 × 65 mm (excluding protruding parts)
IP40 (IEC60529)
PC + ABS
Approx. 130 g
DIN Track
cable length
2m
5m
10m
V680-HAM91/V680-HAM81
model
V680-A60 2m
V680-A60 5m
V680-A60 10m
2
, 10 sweeps in each 3 directions (up/