F3SJ-A

Specifications

F3SJ-A____P14/P30
Model
PNP Output
Sensor type
Version
Setting tool connection
Safety category
Detection capability
Beam gap (P)
Number of beams (n)
Protective height (PH)
Lens diameter
Operating range
Response time
ON to OFF
(under stable light incident
condition)
OFF to ON
Startup waiting time
Power supply voltage (Vs)
Current consumption
Emitter
(no load)
Receiver
Light source (emitted wavelength)
Effective aperture angle (EAA)
Safety outputs (OSSD)
PNP outputs
Auxiliary output 1
PNP outputs
(Non-safety output)
Auxiliary output 2
PNP outputs
(Non-safety output. Function for
Basic System.)
External indicator output
(Non-safety output)
Output operation
Receiver
mode
Emitter
F3SJ-A____P14
Type 4 safety light curtain
Ver. 2
Connectable
Safety purpose of category 4, 3, 2, 1, or B
Opaque objects 14 mm in diameter
9 mm
26 to 180
245 to 1,631 mm
Diameter 5 mm
0.2 to 9 m (protective height 1,640 mm max.), 0.2 to 7 m (protective height 1,655 mm min.)
(Depending on the setting tool, the detection distance can be shortened to 0.5 m.)
1 set, 0245 to 983: 11 ms to 17.5 ms max.
1,055 or higher: 20 ms to 25 ms max.
1 set, 0245 to 983: 44 ms to 70 ms max.
1,055 or higher: 80 ms to 100 ms max.
2 s max. (2.2 s max. for series connection)
24 VDC±20% (ripple p-p10% max.)
To 50 beams: 76 mA max., 51 to 100 beams: 106 mA max., 101 to 150 beams: 130 mA max.,
151 to 180 beams: 153 mA max., 201 to 234 beams: 165 mA max.
To 50 beams: 68 mA max., 51 to 100 beams: 90 mA max., 101 to 150 beams: 111 mA max.,
151 to 180 beams: 128 mA max., 201 to 234 beams: 142 mA max.
Infrared LED (870 nm)
Based on IEC 61496-2.Within±2.5° for both emitter and receiver when the detection distance is 3 m or over
Two PNP transistor outputs, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
allowable capacity load 2.2 F, leak current 1 mA max.
(This can be different from traditional logic (ON/OFF) because safety circuit is used.)
One PNP transistor output, load current 300 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
leak current 1 mA max.
One PNP transistor output, load current 50 mA max., residual voltage 2 V max. (except for voltage drop due to cable extension),
leak current 1 mA max.
Available indicators
Incandescent lamp: 24 VDC, 3 to 7 W
LED lamp: Load current 10 mA to 300 mA max., leak current 1 mA max.
(To use an external indicator, an F39-JJ3N universal indicator cable or an F39-A01P-PAC dedicated external indicator kit is required.)
Safety output 1, 2: ON when receiving light
Auxiliary output 1: Inverse of safety output signals (Operation mode can be changed with the setting tool.)
External indicator output 1: Inverse of safety output signals for a basic system (Operation mode can be changed with the setting
tool.), ON when muting/override for a muting system (Operation mode can be changed with the setting tool.)
Auxiliary output 2: Turns ON when the point of 30,000 operating hours is reached (Operation mode can be changed with the setting
tool.)
External indicator output 2: ON when lock-out for a basic system (Operation mode can be changed with the setting tool.)
ON when muting/override for a muting system (Operation mode can be changed with the setting tool.)
Safety sensors
F3SJ-A____P30
Opaque objects 30 mm in diameter
25 mm
10 to 100
245 to 2,495 mm
1 set: 10 ms to 17.5 ms max.
1 set: 40 ms to 70 ms max.
441