Page 1
RFID SYSTEM V680 Series User’s Manual FL Remote ID V680-HAM42-FRT Antenna V680-HS63-SP ID Tag V680-D1KP66T-SP...
Page 2
Introduction Thank you for purchasing a V680-series RFID System. This manual describes the functions, performance, and application methods needed for optimum use of the V680-series RFID System. Please observe the following items when using the RFID System. • Allow the RFID System to be installed and operated only by qualified specialist with a sufficient knowledge of electrical systems.
Page 3
PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS...
Page 4
Application Considerations < SUITABILITY FOR USE > OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of the products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products.
Performance data given in this manual is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON’s test conditions, and the users must correlate it to actual application requirements.
Page 6
Regulations and Standards The V680-HAM42-FRT and V680-HS63-SP conform to the following overseas regulations and standards. Japan Japan Radio Law Equipment using high frequencies: Inductive Reading/Writing Communications Equipment Conforming standards: Inductive Reading/Writing Communications Equipment; Standard: ARIB STD-T82 The United States, Canada FCC Rules (Federal Communications Commission), IC Rules (Industry Canada) This product complies with Part 15 Subpart C and Part 15 Subpart B of the FCC Rules and IC Rules.
Page 7
Hereby, OMRON Corporation declares that this RFID System, Antenna V680-HS63-SP and Amplifier V680-HAM42-FRT. Amplifier and Antenna are in compliance with essential requirements and other relevant provisions of Directive 1995/5/EC, and satisfy tests for the appropriate requirements of the following relevant standards.
Page 8
6. Turn OFF the Controller power supply before mounting or removing an Antenna or Amplifier. 7. If an error is detected in any Product, immediately stop operation and turn OFF the power supply. Consult with an OMRON representative. 8. Dispose of the Products as industrial waste.
Page 9
Precautions for Correct Use Always observe the following precautions to prevent operation failures, malfunctions, and adverse effects on performance and equipment. 1. Installation Location Do not install the product in the following locations: ・Locations subject to corrosive gases, dust, dirt, metal powder, or salt ・Locations where the specified ambient operating temperature range is exceeded ・Locations subject to extreme temperature changes that may result in condensation ・Locations where the specified ambient operating humidity range is exceeded...
Page 10
・Locations where the specified ambient storage temperature range is exceeded ・Locations subject to extreme temperature changes that may result in condensation ・Locations where the specified ambient storage humidity range is exceeded ・Locations where the product would be directly subjected to vibration or shock exceeding specifications ・Locations subject to contact with water, oil, or chemicals 4.
Meanings of Signal Words ........................5 Product overview..........................13 1.1. Features.............................13 System Configuration .........................13 1.2. Part names and functions ........................14 Part names ..........................14 2.1. I/O Specifications ........................19 2.2. Allocated I/O ........................19 2.2.1. Signal functions ........................20 2.2.2. 2.3. Memory map..........................21 2.4. ID tag communication functions....................22 Operational mode ........................22 2.4.1.
Page 12
3.1.4. Bit clear..........................26 Data fill ..........................27 3.1.5. 3.1.6. Noise measurement......................28 Timing chart ..........................29 3.2. Appendix ............................30 4.1. Specifications..........................30 4.2. Dimensions..........................32...
The RFID system: V680 series employs the electromagnetic induction type, and is a product in accordance with International Standard ISO/IEC18000-3(ISO/IEC15693) of the RFID system. 1.2. System Configuration PLC: FL REMOTE Master unit FL REMOTE ID V680-HAM42-FRT Antenna V680-HS63-SP ID Tag V680-D1KP66T-SP...
2. Part names and functions 2.1. Part names Ethernet connector Power supply connector Display LED Antenna connector Node No. switch Mode switch <Front view> <Bottom view> - Ethernet Connector: Connector for FL REMOTE PIN No Name Description I/O TX_D1+ Tranceive data + output TX_D1- Tranceive data -...
Page 15
- Antenna connector: connector for antenna PIN No Name Description I/O Signal - Analog ground - - Power supply connector: connected to the 24VDC power supply Please use the bundled connector. PIN No Name Description I/O 24VDC terminal 24V - Ground terminal -...
Page 16
- Display LED > DEV(Device Status indicator) Status Meaning Green Normal Serious malfunction Red(blinking) Slight malfunction Unlit Power off >RMT(Remote Status indicator) Status Meaning Green Connected to network/ Transferring FL Remote IO Green (blinking) Connected to network/ No transferring FL Remote IO Green and Red (blinking) Connected to network/ Setting error Duplicate node address...
Page 18
- Node No. switch Please set node no. with the Node No. switch that is used as the low rank value of Internet Protocol address. 192.168.250. **. Item Description Setting method two BCD rotary switches Setting range 01 to 31 - Mode switch Please set the mode of FL REMOTE ID with the mode switch.
2.2.1. Allocated I/O The V680-HAM42-FRT occupies 64 input bits (4 words) and 64 output bits (4 words) of the Programmable Controller. The occupied CIO varies according to the node number that is set by the Node No. switch of V680-HAM42-FRT.
2.2.2. Signal functions <Master unit to Slave unit> Signal Name Description OD0-0 to 7 Data output Output write data to the ID tag OD1-0 to 7 OD2-0 to 7 OD3-0 to 7 Specify start address for reading or writing. ADDR0 to 15 Address Setting range: 0000H to FFFFH...
2.3. Memory map ID tag has a memory area of up to 1 Kbytes. Each address of the memory area specifies one byte. A single byte of data can be written to one address. Address Data 0000H 1block 0007H 0008H 0100H 1000bytes 0200H...
2.4. ID tag communication functions FL remote ID sets the operating mode with the mode switch, selects the command, adds the option that operates the command, and communicates with the ID tag. 2.4.1. Operational mode In the operating mode, there are three modes. 2.4.1.1.
3. Communicating with the plc 3.1. Command correspondence 3.1.1. Data read <Master unit to Slave unit> Signal Length Data Description 0000B Data read 1H to 4H Data length ADDR 0000H to FFFFH Start address <Slave unit to Master unit> Signal Length Data Description...
3.1.2. Data write <Master unit to Slave unit> Signal Length Data Description 0001B Data write 1H to 4H Data length ADDR 0000H to FFFFH Start address - Write data <Slave unit to Master unit> Signal Length Data Description NORM 0 or 1 Normal completion ERR* 0 or 1...
3.1.3. Bit set <Master unit to Slave unit> Signal Length Data Description 0010B Bit set 1H to 4H Data length ADDR 0000H to FFFFH Start address - Bit set data <Slave unit to Master unit> Signal Length Data Description NORM 0 or 1 Normal completion ERR*...
3.1.4. Bit clear <Master unit to Slave unit> Signal Length Data Description 0011B Bit clear 1H to 4H Data length ADDR 0000H to FFFFH Start address - Bit clear data <Slave unit to Master unit> Signal Length Data Description NORM 0 or 1 Normal completion ERR*...
3.1.5. Data fill <Master unit to Slave unit> Signal Length Data Description 0100B Data fill 1H to 4H Data length ADDR 0000H to FFFFH Start address - Data fill data <Slave unit to Master unit> Signal Length Data Description NORM 0 or 1 Normal completion ERR*...
3.1.6. Noise measurement <Master unit to Slave unit> Signal Length Data Description 1111B Noise measurement <Slave unit to Master unit> Signal Length Data Description NORM 0 or 1 Normal completion ERR* 0 or 1 Abnormal completion - Measurement result ID0: Average value (00~63H) ID1:...
3.2. Timing chart ID tag in communication area ID tag BUSY NORM ERR1 ERR_SUB C D E <When ID tag is in the communication area> A:The plc makes TRG “1" (on) and directs the execution to FL REMOTE ID. B:FL REMOTE ID fixes CMD (command), LEN (data length), and ADDR (start address), the communication with the ID tag begins, and BUSY is “1"...
4. Appendix 4.1. Specifications - FL REMOTE ID V680-HAM42-FRT Characteristic Specification Supply voltage 24VDC(20.4VDC to 26.4VDC) Protective conductor Power consumption Less than 6W Ambient temperature Operating:-10 to +55℃, storage: -25 to +65℃ (no freezing, no dew condensation) Ambient humidity Operating: 35 to 85%RH, storage: 35 to 85%RH...
Page 31
- ID Tag V680-D1KP66T-SP Characteristic Specification Memory capacity 1,000 bytes (user area) Memory type EEPROM Data backup time 10 years after writing (85℃ or less) Data overwrite count 100,000 times per address (25℃) Ambient temperature Operating:-25 to +70℃, storage: -40 to +110℃ (no freezing, no dew condensation) Ambient humidity Operating: 35 to 95%RH, storage: 35 to 95%RH...
Need help?
Do you have a question about the V680-HAM42-FRT and is the answer not in the manual?
Questions and answers