Section 3
Functions

Optional Functions

The following optional functions can be enabled by using the mode setting switches (access mode setting,
output mode setting, read mode setting, or write mode setting) and specifying the control signal.
Output Time Operation
Set the output method and time for the normal completion output (NORMAL/STRB), error completion
output (ERR), and data outputs (OD0 to OD15). There are two output methods: OFF delay and fixed
time.
RF Tag position
Fixed time
output
OFF delay
• The output time operation specification depends on the communications mode. A setting error will
occur if an output method that is not supported is set
Communications mode
Standard modes Trigger Mode 1 Designation not required.
V600-compatible
modes
Note1. : The output will continue in Trigger Mode 1 until the trigger input turns OFF.
2. : When it is set to "CONTINUOUS" at the FIXED TIME OUTPUT, it keeps OUTPUT until INHIBIT/TRIG input turns to
OFF.
For detail timing of output time, refer to Section 5 Control I/O Interface, and Section 7 Appendices when using V600
compatible mode.
RFID System
28
User's Manual
Function
Output time operation
Specified by setting the output mode.
Verification
Set the read mode to "VERIFY".
Wire saving
Set the read mode to "DATA READ2".
Write mode
Specified by setting the write mode.
Write protection
Specified using the WRITE_PROTECT external input.
Address shift
Specified using theADR0 to ADR2 external inputs.
Noise check
Specified using the NOISE_IN external input.
Out of communications
In communications
range
range
Fixed output time
ON
OFF
ON
OFF
Output method specification
(See note1.)
Auto Mode 1
OFF delay
Trigger Mode 2 Fixed time
Auto Mode 2
Fixed time
Trigger Mode 3 OFF delay
Auto Mode 3
OFF delay
p.56, p.173
Description
Out of communi-
In communications
cations range
range
Fixed output time
t
ms
1
t
ms
2
OFF delay
Either from "0" to "9"
10 ms("0")/50 ms("1")/500 ms("2") OFFDELAY
10 ms("3")/50 ms("4")/CONTINUOUS("5") (See note2.)
10 ms("3")/50 ms("4")/CONTINUOUS("5") (See note2.)
10 ms("0")/50 ms("1")/500 ms("2") OFFDELAY
10 ms("0")/50 ms("1")/500 ms("2") OFFDELAY
Out of communi-
cations range
t
ms
1
t
ms
2
OFF delay
Output rotary switch setting range