Ratings and Specifications

Sensing method
Item
Model
Sensing distance
3 m, switchable between LONG mode (1 to 3 m) and SHORT mode: (0.05 to 1 m), factory-set to SHORT mode.
Beam gap
25 mm
Number of beams
5
Sensing width
100 mm
Standard sensing object Opaque, 35 mm dia. min.
Light source
Infrared LED (860 nm)
(emission wavelength)
Power supply voltage
12 to 24 VDC±10% (ripple (p-p): 10% max.)
Power consumption
Emitter: 0.6 W max., Receiver: 0.7 W max.
NPN open collector with 100 mA max. at 30 VDC
Control output
NPN open collector output type
Dark-ON or Light-ON (selectable)
Open collector with relay or transistor input
Picking instruction
Indicator ON: Input voltage of 0 to 2 V
indicator input
Indicator OFF: Open (with leakage current of 0.1 mA max.)
Reverse-connection protection, output short protection, and mutual interference prevention function
Protection circuits
(set with frequency switch)
Response time
Operate/Reset: 10 ms max.
Operation indicator (orange), stability indicator (green), and 6 picking indicators (orange),
Receiver
UNI-WIRE Direct Connection Models: Transmission indicator (orange) *3
Indicators
Power indicator (green), different frequency indicator (green), and 6 picking indicators (orange),
Emitter
UNI-WIRE Direct Connection Models: Transmission indicator (orange) *3
Operating: −10° to 55°C, Storage: −25° to 70°C (with no icing or condensation)
Ambient temperature
Ambient humidity
35% to 85% (with no condensation)
Insulation resistance
20 MΩ min. (at 500 VDC)
Dielectric strength
1,000 VAC 50/60 Hz for 1 min
Vibration resistance
10 to 50 Hz, 1.5-mm double-amplitude for 2 hours each in X, Y and Z directions
(destruction)
Shock resistance
500 m/s
(destruction)
Degree of protection
IEC60529: IP62 (with the operation cover closed)
Pre-wired
Connection method
Standard cable length: 5 m *4
Weight (packed state)
Approx. 360 g
Case,
indicator
ABS resin
windows
Materials
Lens
Acrylic resin
Opera-
tion
Nylon (PA6)
cover
Accessories
Instruction manual
*1. The F3W-D052@P Emitters are provided with the external picking indicator output line shown in the following table.
Item
Connection method
Pre-wired (standard cable length: 300 mm)
Output current: 50 mA max.
Electrical specifications
Output voltage: Fixed at Sensor power supply voltage
*2. Response time includes transfer delay time.
*3. The transmission indicator indicates bus transmission status.
*4. The following cable lengths are also available.
F3W-D052A (P): 2 m, 7 m
F3W-D052B (P): 1 m, 3.5 m
http://www.ia.omron.com/
F3W-D052A (P) *1
2
, 3 times each in X, Y and Z directions
F3W-D052AP, F3W-D052BP, F3W-D052UP
Through-beam
F3W-D052B (P) *1
Pre-wired connector
(M12 5-pin connector)
Standard cable length: 2 m *4
Approx. 230 g
4
(c)Copyright OMRON Corporation 2008 All Rights Reserved.
F3W-D
F3W-D052U (P) *1
24 VDC ±10%, ripple (p-p) 10% max.
(supplied by UNI-WIRE SYSTEM,
other power supply also possible)
Emitter/Receiver: 0.6 W max.
Transmission output
(output address set using DIP switch 3
control output address setting switch)
Transmission input
(input address set using DIP switch 2
instruction input address setting
switch)
Operate/release: 39 ms (64-bit), 66 ms
(128-bit), or 120 ms (256-bit) max.*2
Pre-wired
Standard cable length: 2 m
Approx. 220 g