Auto Mode1: VERIFY
Mode setting switch settings
RF Tag position
Communications
with RF Tag
Access Address : 0010 hex
Output Mode : 10 ms OFF delay
Data output
(OD0 to OD15: 16 bits)
A, B. Preparations
C. Canceling communica-
tions prohibition
Reference Data and Read Data Match
D. Start of communications
E. End of communications
F. Clearing results
Reference Data and Read Data Mismatch
G. Start of communications
H. End of communications
I. Clearing results
• At least 10 ms is required for enabling INHIBIT/TRIG input as operation prohibit or clear the data.
• Wait at least 10 ms after switching the R/W input line before performing next process.
• Switch the address shift input (ADR0 to ADR2) at least 10 ms before accessing the RF Tag.
• Switch the reference data input (ID0 to ID15) at least 10 ms before accessing the RF Tag.
• Read the data output (OD0 to OD15) after the NORMAL/STRB output turns ON.
• In Auto Mode, the ID Flag Sensor does not output the error in case when the ID Flag Sensor can not complete the communication
process caused by passing the RF Tag quickly in the communications area of the Antenna before completing the communication or
interfering by electrical noise. Be sure to check the communications carefully when installing the system.
INHIBIT/TRIG
Data intput
0000
(ID0 to ID15: 16 bits)
hex
R/W input
Address shift input
0 hex
(ADR0 to 2: 3 bits)
NORMAL/STRB
ERR output
PARITY output
NOISE_OUT
output
0000 hex
Data Display LED
All OFF
(0 to 15: 16 bits)
A
B
Before starting communications with the RF Tag, turn OFF the R/W input, set the reference data on the data
input bits (ID0 to ID15), and set the address shift input bits (ADR0 to ADR2).
Turn OFF the INHIBIT/TRIG before starting communications.
The ID Flag Sensor will start communications with the RF Tag when the RF Tag enters the communications
area of the Antenna.
If communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the NORMAL/STRB
output and the data output bit (OD0: data match). The VERIFY OK/NG indicator will be lit green, and the data
indicators (0 to 15) corresponding to the reference data will be lit green.
After the RF Tag is out of the communications area of the Antenna, the NORMAL/STRB output and data output bits
(OD0 to OD15) will be turned OFF after the time set for the OFF delay in the output mode time setting has elapsed.
The NORMAL/STRB output , the data output bits (OD0 to OD15) and the Data Display LED can be uncondition-
ally cleared by turning ON the INHIBIT/TRIG input.
The ID Flag Sensor will start communications with the RF Tag when the RF Tag enters the communications
area of the Antenna.
If communications with the RF Tag are completed normally, the ID Flag Sensor will turn ON the NORMAL/STRB
output and the data output bit (OD7: data mismatch). The VERIFY OK/NG indicator will be lit red, and the data
indicators (0 to 15) corresponding to the reference data will be lit green.
After the RF Tag is out of the communications area of the Antenna, the NORMAL/STRB output and data output bits
(OD0 to OD15) will be turned OFF after the time set for the OFF delay in the output mode time setting has elapsed.
The NORMAL/STRB output, the data output bits (OD0 to OD15) and the Data Display LED can be uncondition-
ally cleared by turning ON the INHIBIT/TRIG input.
In communi-
cations range
Verify-
ing
Reference data1
Address shift data
3 ms
OFF delay time
0
0001 hex
0000 hex
Reference data1 (green)
C
D
E
F
Reference data and read data match Reference data and read data do not match.
Section 5
Control I/O Interface
In communi-
cations range
Verify-
ing
Reference data2
3 ms
OFF delay time
0080 hex
0000 hex
Reference data2 (green)
G
H
I
RFID System
User's Manual
61

Advertisement

Table of Contents
loading

Table of Contents