2H0/2HZ
(18) Image center does not align with the original center.
Copy example
Misadjusted image center line.
Misadjusted scanner center line.
Original is not placed correctly.
1-4-38
Causes
Check procedures/corrective measures
Run maintenance item U034 to readjust the center line of
image printing (see page 1-3-21).
Run maintenance item U067 to readjust the scanner leading
edge registration (see page 1-3-29).
Place the original correctly.