U093 Setting: Density In Photo Mode; U099 Adjusting Original Size Detection - Kyocera KM-2560 Service Manual

Hide thumbs Also See for KM-2560:
Table of Contents

Advertisement

2H0/2HZ
Maintenance
item No.
Setting: Density in photo mode
U093
1. Select the item to be set.
2. Adjust the setting using the +/- or numeric keys.
Display
PHOTO DARKER
PHOTO LIGTER
Increasing the setting makes the change in density larger, and decreasing it makes the change smaller.
3. Press the start key. The value is set.
4. To return to the screen for selecting an item, press the stop key.
Supplement
While this maintenance item is being executed, copying from an original is available in interrupt copying mode
(which is activated by pressing the system menu key).
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Adjusting original size detection
U099
Description
Checks the operation of the original size detection sensor and sets the sensing threshold value.
Purpose
To adjust the sensitiveness of the sensor and size judgement time if the original size detection sensor mal-
functions frequently due to incident light or the like.
Method
1. Press the start key.
2. Select the item. The screen for executing each item is displayed.
Display
DATA
B/W LEVEL
Method to display the data for the sensor
1. Place the original and close the original cover or DP. The detection sensor transmission data is dis-
played.
Display
ORIGINAL AREA R
ORIGINAL AREA G
ORIGINAL AREA B
ORIGINAL AREA
SIZE SW L
2. To return to the screen for selecting an item, press the stop key.
1-3-40
Description
Description
Change in density when manual density is set dark 0 to 3
Change in density when manual density is set light 0 to 3
Description
Displaying detection sensor transmission data
Setting detection sensor threshold value
Setting original size judgment time
Description
Detected original width size (R)
Detected original width size (G)
Detected original width size (B)
Detected original width size
Displays the original detection switch ON/OFF
Setting
Initial
range
setting
0
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Km-3060