2H0/2HZ
Connector
Pin No.
TB1
TB
Connected
TB2
to the AC
inlet and
TB3
main power
switch
TB4
1
YC1
Connected
2
to the cas-
3
sette heater
4
1
YC2
Connected
2
to the cas-
3
sette heater
4
1
YC3
Connected
2
to the fuser
heater M/S
3
YC4
1
Connected
2
to the main
3
PWB
4
5
6
7
8
9
10
YC5
1
Connected
2
to the inter-
face PWB
YC6
1
Connected
2
to the cool-
ing fan
motor 3
2-3-2
Signal
I/O
LIVE
I
NEUTRAL
I
LIVE
O
LIVE
I
LIVE
O
N.C.
-
N.C.
-
NEUTRAL
O
LIVE
O
N.C.
-
N.C.
-
NEUTRAL
O
NEUTRAL
O
NEUTRAL
O
LIVE
O
+5V
O
+5V
O
+5VSL
O
+12VSL
O
+24VSL
O
GND
-
GND
-
GND
-
GND
-
GND
-
GND
-
+5V
O
FAN3DRN
O
+24VSL
O
Voltage
120 V AC
AC power input
220-240 V AC
120 V AC
AC power input
220-240 V AC
120 V AC
AC power output to MSW
220-240 V AC
120 V AC
AC power input from MSW
220-240 V AC
120 V AC
AC power output
220-240 V AC
-
Not used
-
Not used
120 V AC
AC power output
220-240 V AC
120 V AC
AC power output
220-240 V AC
-
Not used
-
Not used
120 V AC
AC power output
220-240 V AC
120/0 V AC
FH-M: On/Off
220-240/0 V AC
120/0 V AC
FH-S: On/Off
220-240/0 V AC
120 V AC
AC power output to FM-M/S
220-240 V AC
5 V DC
5 V DC power output to MPWB
5 V DC
5 V DC power output to MPWB
5 V DC
5 V DC power output to MPWB
12 V DC
12 V DC power output to MPWB
24 V DC
24 V DC power output to MPWB
-
Ground
-
Ground
-
Ground
-
Ground
-
Ground
-
Ground
5 V DC
5 V DC power output to IFPWB
0/24 V DC
CFM3: On/Off
24 V DC
24 V DC power output to CFM3