Connector
Pin No.
YC1
A1
Connected
A2
to the over-
A3
flow sensor,
A4
cleaning
lamp, toner
A5
sensor,
A6
humidity
A7
sensor,
toner feed
A8
motor,
A9
developing
A10
PWB, drum
PWB and
A11
fuser unit
A12
A13
A14
A15
A16
B1
B2
B3
B4
B5
B6
B7
B8
B9
B10
B11
B12
B13
B14
B15
B16
YC2
1
Connected
2
to the poly-
3
gon motor,
4
cooling fan
motor 1,
5
toner con-
6
tainer sen-
7
sor and
toner con-
8
tainer detec-
9
tion switch
10
15
16
Signal
I/O
GND
-
TONEFUL
I
+5V
O
+24V
O
ERASE3N
O
ERASE2N
O
ERASE1N
O
GND
-
DEVDETN
I
+5V
O
+5V
O
HUMID_SDA
I/O
GND
-
HUMID_SCL
O
TNMOT24V
O
TNMOTREM
O
IUID1DETN
I
GND
-
IUID1SDA
I/O
IUID1SCL
O
+5V
O
IUID2DETN
I
GND
-
IUID2SDA
I/O
IUID2SCL
O
+5V
O
THEAMA_GND
-
THEAMA
I
FUFMLTN
O
FIXTHCEN
I
N.C.
-
+3.3V
O
+24VSL
O
GND
-
PLGDRN
O
PLGRDYN
I
PLGCLKN
O
FAN1 DRN
O
FAN1 POW
O
GND
-
COUNTSENS
I
+5VSL
O
CONTSW
I
GND
-
Voltage
-
Ground
0/5 V DC
OFS: On/Off
5 V DC
5 V DC power output to OFS
24 V DC
24 V DC power output to CL
0/24 V DC
CL: On/Off
0/24 V DC
CL: On/Off
0/24 V DC
CL: On/Off
-
Ground
0/5 V DC
TNS: On/Off
5 V DC
5 V DC power output to TNS
5 V DC
5 V DC power output to HUMS
Analog
HUMS detection voltage signal
-
Ground
0/5 V DC (pulse)
HUMS clock signal
24 V DC
24 V DC power output to TFM
0/24 V DC
TFM: On/Off
0/5 V DC
Developing unit detection signal
-
Ground
0/5 V DC (pulse)
Developing unit EEPROM data signal
0/5 V DC (pulse)
Developing unit EEPROM clock signal
5 V DC
5 V DC power output to developing unit
0/5 V DC
Drum unit detection signal
-
Ground
0/5 V DC (pulse)
Drum unit EEPROM data signal
0/5 V DC (pulse)
Drum unit EEPROM clock signal
5 V DC
5 V DC power output to drum unit
-
Ground
Analog
FTH1 detection voltage signal
0/5 V DC
Fuse cut signal
Analog
FTH2 detection voltage signal
-
Not used
3.3 V DC
3.3 V DC power output to FUPWB
24 V DC
24 V DC power output to PM
-
Ground
0/24 V DC
PM: On/Off
0/5 V DC
PM ready signal
0/5 V DC (pulse)
PM clock signal
0/24 V DC
CFM1: On/Off
24 V DC
24 V DC power output to CFM1
-
Ground
0/5 V DC
TCS: On/Off
5 V DC
5 V DC power output to TCS
0/5 V DC
TCDSW: On/Off
-
Ground
2H0/2HZ
Description