Epson Artisan 810/835/837/710/725/730/Epson Stylus Photo PX810FW/TX810FW/PX820FWD/TX820FWD/PX830FWD/PX710W/TX710W/PX720WD/TX720WD/PX730WD/TX730WD
2.
Remove the screw (x1) that secures the Decoration Plate Left Upper Sub and
release the hook (x1) of the Decoration Plate Left Upper Sub, and then
remove the Decoration Plate Left Upper Sub.
Figure 9-40. Removing the Decoration Plate Left Upper (2)
Artisan 837/730/PX830FWD/PX730WD/TX730WD
Decoration Plate Left Upper Sub
Hook
C.B.P. 3x10 (6±1Kgfcm)
Disassembly/assembly
9.4.2.17 Upper Housing
This section describes the disassembly/reassembly procedures of the
C H E C K
Upper Housing for Artisan 730/PX730WD/TX730WD.
P O I N T
The disassembly/reassembly procedures for Artisan 837/
PX830FWD differ from those for Artisan 730/PX730WD/
TX730WD, therefore, see
procedures.
Parts/Components need to be removed in advance:
Scanner Unit/Decoration Plate Left Upper/Decoration Plate Left Upper Sub/Paper
Guide Top Assy
Removal procedure
The grounding wire is attached to the frame with a screw. Be careful
C A U T I O N
not to deform the Frame when removing the screw.
1.
Remove the screw (x1) and release the grounding wire.
Grounding wire
Figure 9-41. Releasing the Grounding Wire
Revision G
"9.4.2.2 Upper Housing" (p.294)
for the
C.B.S. 3x6 (8±1Kgfcm)
Confidential
309