Bosch DSA E-Series (E2700) Installation Manual page 64

Table of Contents

Advertisement

64
en | Turning on the power and checking for problems in an E2700 controller-drive tray configuration
LEDs on the ESM canister
Location
LED
1
Host link 1 fault
2
Host link 1 active
3
Host link 2 fault
4
Host link 2 active
5
Ethernet link active
6
Ethernet link rate
7
ESM expansion link
fault
8
ESM expansion link
active
2015.10 | V2 | DOC
1
2
3
4
9
10
1 1
12
Color
Amber
At least one PHY of the four
connectors is working, but
another PHY cannot establish
the same link to the device
connected to the Host IN
port connector.
Green
At least one of the four PHYs
in the In port is working, and
a link exists to the device
connected to the Host In
connector.
Amber
At least one PHY of the four
connections is working, but
another PHY cannot establish
the same link to the device
connected to the Host In
port connector.
Green
At least one of the four PHYs
in the IN port is working, and
a link exists to the device
connected to the Host In
connector.
Green
The link is up. (The LED
blinks when there is activity.)
Green
There is a 100BASE-T rate.
Amber
At least one of the four PHYs
in the Out port is working,
but another PHY cannot
establish the same link to the
Expansion Out connector.
Green
At least one of the four PHYs
in the Out port is working,
and a link exists to the
device connected to the
Expansion Out connector.
Installation manual
5
6
7
8
90001-01
On
No link error has occurred.
A link error has occurred.
No link error has occurred.
A link error has occurred.
The link is not active.
There is a 10BASE-T rate.
Normal status.
A link error has occurred.
DSA E-Series (E2700)
Off
Bosch Sicherheitssysteme GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dsx-n6d6xx-60atDsa-n2e7xx-xxatDsx-n1d6xx-12at

Table of Contents