Commissioning
of Prototype
Machine using
Sample PLC
Switching on and prepare for commissioning
V70 Drive:
Loading of "Default data"
Remove drive bus cable from terminal X10
Press M repeatedly (until "FUnC" is displayed)
Press OK
Press ▼(until "dEFAUL" is displayed)
Press OK for more than 2 sec
Screen will go blank (wait about 20sec)
(Screen will display "S OFF" or a fault code)
Saving data.
Press M repeatedly (until "FUnC" is displayed)
Press OK
Press ▼(until "SAvE" is displayed)
Press OK for more than 2 sec
Screen will go blank (wait about 20sec)
(Screen will display "S OFF" or a fault code)
Replace drive bus cable to terminal X10
Commissioning Guide
Step 5
Before the control can be commissioned, loading of standard NC data
has to be carried out, the password has to be set to manufacturer, and
the time and the date have to be set.
Setting of the password.
For detailed information refer to :-
Commissioning manual page 92
To set the password :-
Press button
Press SK
Type in "SUNRISE"
Press SK
Setting of the time and date.
For detailed information refer to :-
Commissioning manual page 93
To set the time and date :-
Press SK
Press SK
Type in time and date using the key-
board and the
button
Page 28
s
+
and
808D ADVANCED Turning and Milling

Advertisement

loading