Download Print this page

Siemens SINUMERIK 808D ADVANCED Training Manual page 27

Hide thumbs Also See for SINUMERIK 808D ADVANCED:

Advertisement

Commissioning
of Prototype
Machine using
Sample PLC
Switching on and prepare for commissioning
4. Check that the status LED's on the front face of the V70 drives are in a
ready state.
V70 digital drive display at this stage, the status should be S - off.
For detailed information refer to :-
Commissioning manual page 81
Status on power up with
Status on power up with
absolute encoder
incremental encoder
Status description on SINAMICS V70
Item
Description
8.8.8.8.8.8
Initializing the drive, will take 20 –30 sec
during the process
- - - - - - -
Drive is busy
S - Off
Operating display: servo off
r
- 0
Drive is running properly
A 01...A 45
Alarm code
F 01...F 45
Fault code
808D ADVANCED Turning and Milling
Step 5
LED status indicators
Two LED status indicators (RDY and COM) are available to indicate drive
readiness status and communication status respectively.
Status LED's indicator
RDY
COM
Page 27
s
colour
Status
description
24v control board
-
Off
power supply is miss-
ing
Green
Continuously lit
Drive is ready
Enable signal is
Continuously lit
missing or drive is in
Red
start-up states
Flash at 1Hz
Alarms or faults occur
Orange
Flash at 2Hz
Servo drive is located
Communication with
-
Off
CNC is not active
Communication with
Flash at 0.5Hz
CNC is active
Green
SD card operating
Flash at 2Hz
(read or write)
Communication with
Red
Continuously lit
CNC is in error
Commissioning Guide

Advertisement

loading