Commissioning
of Prototype
Machine using
Sample PLC
Commissioning the prototype
Create PLC
alarm texts
For detailed information
refer to :-
Commissioning manual
page 103
You can edit the PLC user alarm text either directly on the HMI, or off line
by transferring the file using a USB stick.
Vertical SK's allow you to import and export the text file from the HMI, and
SK that that allows the text file to be directly edited on the HMI.
Import the backup alarm text into the PPU
Export the finished alarm text from the PPU
Edit the alarm text
To continue press the SK
808D ADVANCED Turning and Milling
Step 9
Drive
configuration
For detailed information
refer to :-
Commissioning manual
page 104
V70 Drive:
Set "address data" for each axis:
Remove drive bus cable from terminal X10
Press M repeatedly (until "FUnC" is displayed)
Press OK
Press ▼(until "Addr" is displayed)
Press OK
Press ▼(until desired address is displayed)
Press M
Press ▼(until "SAvE" is displayed)
Press OK
Screen will go blank (wait about 20sec)
If "SAvE" is displayed
Press M (2 times)
(Screen will display "S OFF" or a fault code)
Replace drive bus cable to terminal X10
Drives must now be powered off/on