Installing hardware expansions
6.4 Expansion modules
6.4.2

Installing expansion modules

Requirement
● The device is disconnected from the power network.
● The device is opened.
Procedure
Note
The device comes with three long brackets for modules with low mounting height. Use the
long brackets instead of the ones installed.
60
1. Hold the rod
on both ends and pull it out
with the module brackets facing up.
2. Remove the cover plate
the expansion module.
3. Insert the expansion module
slot.
4. Secure the expansion module with the
designated screw.
5. Install the rod with the module brackets.
6. Remove the bracket
expansion module.
7. Secure the bracket with the designated
screw.
If you are installing a short expansion
module, remove the locking screw from the
retainer and install it in the opposite hole.
8. Close the device.
Operating Instructions, 06/2011, A5E03473780-01
of the slot for
into the
and place it on the
SIMATIC IPC547D